trueintelligence.now

RLT-FRO · DIY pilot TI-001 · Independent research companion · Proposed collaboration

RLT-FRO · Develop It Yourself

Magnetic source attribution

RLT-TI-004 · Foundational engineering gate · planned

Forward models, calibration, identifiability and uncertainty.

Research specification

November PDF pp. 2 and 5 identifies magnetic source attribution as the first measurement gate.

y = A_H h + A_M m + A_E e + noise

Proposed mathematical abstraction: test rank, null spaces, conditioning and controlled current interventions. A single measured sum does not uniquely determine unconstrained components. A calibrated forward model can support conditional identifiability; physical calibration remains necessary.

Return unresolved when evidence cannot support a source label. Filtering alone does not establish source identity.

Synchronized recordings versus synchronized sources

One device-current pulse detected by two magnetometers is a common-source event. A shared clock establishes coincidence in time; source attribution is required before interpreting it as coordination between independent physical sources. Our mathematical counterexamples distinguish phase locking from coupling and source identity.

Controlled-excitation design criterion

For readings y = H + kI + e with invariant intercept H, exactly known distinct currents I₁ and I₂, and additive reading errors bounded by ε, the coupling estimate k̂ satisfies:

|k̂ − k| ≤ 2ε / |I₂ − I₁|

For ε ≥ 0 and target coupling error τ > 0, a sufficient current separation is:

|I₂ − I₁| ≥ 2ε / τ

These are mathematical results under the stated model, not measurements or hardware requirements validated for a wearable. Calibration, movement, nonlinearity, current uncertainty and physical feasibility remain experimental questions.

Lean source: coupling_design_criterion

Source and implementation links

Leading specifications · Engineering roadmap · Independent repository